4shared

Specification
  • Repetition rate: 1050 Hz
  • Intelligent Thermal Effect Control
  • 0.54 mm beam size, Super-Gaussian profile (FWHM)
  • Beam delivery – flying spot with Automatic Fluence Level Adjustment
  • Eye tracking: 1050 Hz sampling rate
  • Zero Latency eye tracker
  • Pupil and limbus tracking: Pupil Centroid Shift Compensation, Automatic Pupil Size Control
  • 7 th dimension: Latency-Free Tracking
  • Particle aspiration system with unique airflow design
  • ORK-CAM module: Refractive treatment
  • PresbyMAX module: Presbyopia treatment (per procedure fee)
  • PALK-CAM module: Therapeutic treatment (per procedure fee)
  • PTK-CAM module: Therapeutic treatment
  • 90° swivelling laser arm
  • Up to 90° swivelling patient bed (optional motor drive)
  • Panel PC – touch screen monitor, pivotable on 2 axes,additional dot-matrix display, washable keyboard with integrated touchpad
  • Working distance of 235 mm
Optional Features
  • Online pachymetry
  • Diagnostic slit lamp – swivelling on 2 axes, 4 selectable diaphragms
  • SCHWIND CXL-365 vario for corneal collagen crosslinking
  • Video system
  • Cross laser for patient adjustment
  • SCHWIND MEDNET network solution 
 
 
SCHWIND AMARIS® 1050RS
The evolutionary premium model 

1050 Hz pulse rateAMARIS-1050RS

The innovative laser system delivers an unsurpassed repetition rate of 1050 Hz – currently the highest of all excimer lasers on the market – and consequently an extremely short ablation time of just 1.3 seconds per dioptre. That means even greater safety and comfort for the patient. The risk of the cornea drying out is minimised, and the length of time the patient has to fixate on the green light is reduced. It is a performance leap that brings maximum safety and enhanced patient comfort.

 


0.54 mm spot size, Super-Gaussian spot profile (FWHM)
With the extremely small spot size and the Super-Gaussian beam profile an exceptionally smooth and tissue saving ablation is achieved

Automatic Fluence Level Adjustment (AFLA)AFLA_RGB-E_46f4971b30

The Automatic Fluence Level Adjustment (AFLA) method ensures an ideally balanced ration between the total number of laser pulses and the energy delivered. About 80 percent of the ablation is performed with a high fluence value. For the fine work – the remaining 20 percent – the laser system automatically switches to a lower fluence. 


1,050 Hz eye tracking
The eye tracker camera monitors the position of the eyes 1050 times per second with a latency time of 1.6 milliseconds. Altogether, the total reaction time of the laser system is only three milliseconds

Seven_dimensionsActive 7D eye tracking

The 7D active eye tracker impresses through a number of benefits: Apart from the linear movements (1st and 2nd dimensions) it compensates rolling movements of the eye (3rd and 4th dimensions). Compensation of the eye’s rotation around its optical axis is achieved with the static and dynamic Advanced Cyclotorsion Control (5th dimension). Movements along the z-axis (sixth dimension) are actively compensated by means of the z-tracking. Automatic pupil size control and pupil centroid shift compensation ensure additional safety.

Latency-Free Tracking in the 7th dimension
The new, ground-breaking Latency-Free Tracking considers the time factor, i.e. the 7th dimension. Latency-Free Tracking compensates for eye movements that occur in the period between acquisition of the eyetracker image and triggering of the subsequent laser pulses.